PURELAB flex 2

PURELAB® flex 2

Perfect water purity for analytical and life science application.

Features
  • Guaranteed water purity  Full recirculation through the UV lamp and purification pack right to the point of use for peace of mind.
  • Intuitive flexible dispense  Clearwater purity display for absolute confidence as you dispense.
  • Real-time TOC monitoring  Provides complete confidence in organic purity by reducing the level of organics for critical applications.
  • Easy to maintain  Easy access to the consumables through the front door panels mean that maintenance time is reduced, with less disruption to your work.
  • Data capture  Download all of the data to USB for system performance validation.

Ideally suited for: Mass Spectrometry, Molecular biology, Electrochemistry, Atomic Spectroscopy, Liquid Chromatography, Gas Chromatography, Immunochemistry, Spectrophotometry, Media / Buffer prep, General chemistry
 

Designed for the laboratory of today. Reliable delivery of Ultrapure Type I water

The award-winning PURELAB flex 2 system provides perfect water purity for analytical and life science applications which require RO type III water up to ultrapure type I (18.2 MΩ.cm) water. It allows you to focus on routine test work without concern about the water quality affecting test results.

"The PURELAB flex 2 is a very successful system both technically and aesthetically. We are very satisfied with our choice. The compact design, easy operation and maintenance are ideal. The PURELAB flex is ready for use very quickly after it is switched on. It has a good flow rate with a 0.2µm point-of-use-filter fitted to the dispenser. It does not cause any problems to our daily requirements."

DIETER DIRK, SENIOR TECH & HEAD OF LABORATORY 
OLSBERG VOCATIONAL COLLEGE, GERMANY

Tech Specs

PRODUCT SPECIFICATIONSPURELAB FLEX 1PURELAB FLEX 2
Dispense flowrateUp to 2.0 l/minUp to 2.0 l/min
Inorganics (resistivity at 25°C)As per feedwater18.2 MΩ.cm
Organics (TOC)Dependant on feedwater<5 ppb
Bacteria<0.1 CFU/ml *<0.001 CFU/ml *
Bacterial endotoxinN/A<0.001 EU/ml *
pHEffectively neutralEffectively neutral
Silica<2 ppm<2 ppm
DNaseN/A<5 pg/ml
RNaseN/A<1 pg/ml
Daily usage (max)100 l/day100 l/day
Daily usage (min)1 l/day10 l/day
Delivery flow rateUp to 2 l/minUp to 2 l/min
PRODUCT SPECIFICATIONSPURELAB FLEX 1PURELAB FLEX 2
Dispense flowrateUp to 2.0 l/minUp to 2.0 l/min
Inorganics (resistivity at 25°C)As per feedwater18.2 MΩ.cm
Organics (TOC)Dependant on feedwater<5 ppb
Bacteria<0.1 CFU/ml *<0.001 CFU/ml *
Bacterial endotoxinN/A<0.001 EU/ml *
pHEffectively neutralEffectively neutral
Silica<2 ppm<2 ppm
DNaseN/A<5 pg/ml
RNaseN/A<1 pg/ml
Daily usage (max)100 l/day100 l/day
Daily usage (min)1 l/day10 l/day
Delivery flow rateUp to 2 l/minUp to 2 l/min

* With POU filter fitted

Consumables

POU Filter
Impact of Overuse

Potential recontamination of purified water and reduced flow rates

Point-of-use Filter
Part Number
LC145
Life expectancy
3 months
DI Pack
Impact of Overuse

Weakly bound ions are released back into the water reducing resistivity

DI Pack
Part Number
LC208
Life expectancy
12 months
UV Light
Impact of Overuse

Uncontrolled bacterial contamination and TOC levels are not reduced

UV Light
Part Number
LC210
Life expectancy
12-18 months
Impurities Removed
POU Filter
Impact of Overuse

Potential recontamination of purified water and reduced flow rates

Point-of-use Filter
Part Number
LC145
Life expectancy
3 months
DI Pack
Impact of Overuse

Weakly bound ions are released back into the water reducing resistivity

DI Pack
Part Number
LC208
Life expectancy
12 months
UV Light
Impact of Overuse

Uncontrolled bacterial contamination and TOC levels are not reduced

UV Light
Part Number
LC210
Life expectancy
12-18 months
Impurities Removed

FAQs

What is a PURELAB flex 2 system?

PURELAB flex 2 is an Ultrapure (Type I) polisher It produces ultrapure type I (18.2MΩ.cm) from pre-purified water.

What type of applications are suitable for water dispensed from the PURELAB Flex 2 system?

PURELAB flex 2 is used for a number of applications including electrochemistry, electrophoresis, GFAAS (Graphite Furnace Atomic Absorption Spectrophotometry), HPLC ,IC (Ion chromatography), mammalian & bacterial cell culture, etc.

What are the benefits of the PURELAB Flex 2 system?

PURELAB Flex 2 offers customers a range of benefits from being intuitive and easy to use , easy to install and commission, flexible dispensing which allows customers to dispense water into a range of container sizes and shapes. It uses minimal lap space, is easy to operate and maintain and can be used for a wide range of lab applications. Other benefits includes real-time TOC monitoring which is calculated every 2-3 seconds to give a real time TOC reading for maximum assurance; water quality monitoring up to the point of dispense to help ensure valuable parameters are provided at all times and inbuilt periodic recirculation to help minimise biofilm build up which can affect some applications.

 

WHITEPAPER

5 steps to a biosafe lab

5 Steps to a BioSafe Lab

Fill in the form below to download our whitepaper which will take you through some of the key criteria to consider when designing, building and using biosafety laboratories at different levels, whether starting from scratch, or retrofitting your lab to be at a higher biosafety level than currently.